Range Hood Size Calculator: How Many CFM Do I Need?
Use this range hood size calculator to determine the right CFM and width for your kitchen ventilation. Enter your cooktop width, burner output, and ducting details to get a realistic hood recommendation — plus practical guidance on capture area, duct sizing, make-up air, and noise.
Best Range Hood for You:
Range Hood Size Calculator: A Complete Guide to CFM, Capture Area, and Kitchen Ventilation
A range hood is one of the most misunderstood appliances in the kitchen. Many homeowners choose a hood based on how it looks or how much it costs, then discover too late that it cannot keep up with their cooking — grease builds up on cabinets, smoke lingers, and odors spread through the house. The question "how many CFM do I need?" has a straightforward answer, but the real-world performance of a range hood depends on much more than the CFM number on the box. This range hood size calculator estimates the airflow you need based on cooktop width, burner output, hood type, and ducting. But the number it produces is only the beginning: capture area, duct diameter, duct length, make-up air, and noise all determine whether your hood actually works. This guide explains the reasoning behind the calculator and the practical factors that separate a quiet, effective ventilation system from a loud, expensive disappointment.
What Does CFM Mean for a Range Hood?
CFM stands for cubic feet per minute — the volume of air the hood can move in one minute. A 300 CFM hood moves 300 cubic feet of air per minute, which is enough to clear smoke and steam from a standard residential cooktop under normal conditions. CFM is the most commonly cited specification for range hoods, but it is not the only one that matters. A hood rated at 900 CFM with undersized ducting may only deliver 500 CFM in practice, while a well-designed 600 CFM hood with proper ducting can outperform it. The CFM rating on a hood is usually measured at zero static pressure (free air), which never happens in a real installation. Every foot of duct, every elbow, and every transition adds resistance, reducing actual airflow. That is why the calculator asks for duct size, duct run length, and the number of elbows — these factors can cut real-world airflow by 20–50% compared with the free-air rating. When shopping, look for a hood's performance at a realistic static pressure (often listed as 0.25 in. w.g.), not just the free-air CFM.
The Two Core Sizing Rules: Width and CFM
Range hood sizing rests on two separate rules that must both be satisfied. The first is the width rule: the hood should be at least as wide as the cooktop, and ideally 3–6 inches wider. A 30-inch cooktop needs a 30-inch hood at minimum; a 36-inch cooktop needs a 36-inch hood. The extra width provides capture area around the edges of the burners, where smoke and steam tend to drift. This is why professional kitchens often use hoods that are 6 inches wider than the cooking surface on each side. The second rule is the CFM rule, and there are several ways to calculate it. The most common is based on the total BTU output of the burners: divide total BTU by 100 to get the minimum CFM. A 40,000 BTU cooktop would need about 400 CFM. For electric and induction cooktops, which do not produce combustion byproducts, a simpler rule is based on width: about 10 CFM per inch of cooktop width, so a 30-inch electric cooktop needs roughly 300 CFM. For gas ranges, 100 CFM per 10,000 BTU is the standard starting point, but high-output pro ranges and wok cooking need more. This calculator applies both rules and uses the higher of the two, then adjusts for hood type and ducting.
Width Rule: Why the Hood Should Be Wider Than the Cooktop
The capture area of a hood is the footprint over the cooking surface where rising smoke, steam, and grease are drawn into the hood. A hood that is exactly the same width as the cooktop has a capture area that ends at the edge of the burners, so any smoke that drifts sideways — which happens constantly with boiling water, frying, and high-heat searing — escapes into the kitchen. A hood that is 3–6 inches wider on each side creates a buffer zone that catches that drifting plume. For island cooktops, the drift is even worse because there are no walls to contain the plume, which is why island hoods are typically sized 6 inches wider than the cooktop and rated for higher CFM. For wall-mounted hoods, the back wall helps contain the plume, so a hood that matches the cooktop width can be acceptable, though a wider hood is still better. The calculator applies a 6-inch widening for island hoods and a small buffer for wall-mounted designs, then reports the recommended hood width alongside the CFM.
CFM Rule 1: BTU-Based Sizing for Gas Ranges
Gas burners produce heat, moisture, and combustion byproducts, and the ventilation requirement scales with the burner output. The widely used rule of thumb is 100 CFM for every 10,000 BTU per hour of total burner output. A standard 30-inch gas range with four 9,000 BTU burners totals 36,000 BTU, which works out to 360 CFM. A pro-style 36-inch range with two 18,000 BTU power burners and four 12,000 BTU burners totals 84,000 BTU, which works out to 840 CFM. A 48-inch commercial-style range with six 18,000 BTU burners totals 108,000 BTU, requiring over 1,000 CFM. These numbers assume typical residential cooking; if you frequently sear at high heat, use a wok, or cook with a lot of oil, add 20–30%. Some manufacturers publish their own recommended CFM per burner, and those recommendations should take precedence because burner design affects how much of the heat actually escapes into the room. The calculator uses the standard 100 CFM per 10,000 BTU rule and lets you select a "high-output" or "wok" cooking style to apply the extra margin.
CFM Rule 2: Width-Based Sizing for Electric and Induction
Electric and induction cooktops do not produce combustion gases, so the ventilation requirement is driven by moisture, odors, and grease rather than burner output. The common residential rule is 10 CFM per inch of cooktop width, which gives 300 CFM for a 30-inch cooktop and 360 CFM for a 36-inch cooktop. For induction, the heat is transferred directly to the pan with very little waste heat, so a hood can often run at lower speeds and still be effective. However, searing and frying still produce smoke and grease, so do not undersize the hood just because the cooktop is induction. For electric coil and radiant cooktops, the 10 CFM per inch rule works well as a baseline. If your cooktop has high-power elements (for example, a 3,000 W or larger element) and you use them for searing, consider stepping up one size. The calculator treats electric and induction separately from gas and uses width-based sizing for those options, then merges the result with the BTU rule when gas is selected.
Ducting: The Most Common Reason Hoods Underperform
The ducting is the part of the ventilation system that most people overlook, and it is the most common reason a powerful hood feels weak. Airflow through a duct is limited by resistance, which increases with duct length, the number of elbows, and — most dramatically — with smaller duct diameter. A 300 CFM hood connected to a 4-inch duct will not deliver 300 CFM; the small duct restricts flow so much that the hood may only move 150–200 CFM. For hoods rated above 400 CFM, a 6-inch duct is the practical minimum, and 7- or 8-inch duct is better for high-CFM pro hoods. A 3.25 × 10-inch rectangular duct is common in wall installations but has less capacity than 6-inch round duct, and it is more prone to grease accumulation because of the flat top surface. Every 90-degree elbow adds resistance equivalent to several feet of straight duct — often 5–10 feet of equivalent length. The calculator accounts for duct size, run length, and elbow count, and it flags when the ducting is likely to choke the hood's rated airflow. As a rule of thumb, if the calculated CFM exceeds 500, use at least 6-inch duct; if it exceeds 900, use 8-inch duct.
Static Pressure and Real-World Airflow
Every duct system has static pressure, measured in inches of water gauge (in. w.g.). A straight, short 6-inch duct might have 0.05–0.1 in. w.g. of static pressure, while a long, winding 4-inch duct might have 0.5 in. w.g. or more. Hood manufacturers publish performance curves that show airflow at different static pressures, and a hood rated at 600 CFM at 0 in. w.g. might only deliver 400 CFM at 0.25 in. w.g. This is why two hoods with the same CFM rating can perform very differently in real kitchens. When comparing models, look for the airflow rating at 0.25 in. w.g., which is a realistic residential static pressure. If the manufacturer only publishes free-air CFM, assume the real airflow will be 20–30% lower unless the ducting is short and straight. The calculator applies a simplified resistance model to estimate real airflow, but for critical installations — such as a pro range in a busy kitchen — consult the manufacturer's performance curve for the specific hood.
Hood Types and How They Affect Sizing
Wall-mount chimney hoods are the most efficient because the back wall helps contain the plume, so they can be sized closer to the cooktop width. Under-cabinet hoods are similar but often have lower-profile capture areas, so they benefit from wider sizing and higher CFM. Island hoods have no walls to help contain smoke and steam, so they need to be 6 inches wider than the cooktop and rated for 20–30% more CFM than a comparable wall hood. Insert (or liner) hoods are built into custom cabinetry and are usually sized to fit the opening, so the capture area and CFM must be matched to the cooktop and the cabinet dimensions. Downdraft hoods are installed behind or beside the cooktop and pull air downward, which is less effective at capturing rising smoke and steam; they often need higher CFM and are not recommended for high-heat cooking. The calculator lets you select the hood type and adjusts the recommended CFM and width accordingly.
Make-Up Air: The Hidden Requirement for High-CFM Hoods
A range hood removes air from the house, and that air has to come from somewhere. In a tightly sealed modern home, a 600+ CFM hood can create negative pressure that causes backdrafting of gas appliances, pulls air through gaps and cracks, and makes the hood less effective because it is fighting for air. Building codes in many jurisdictions require make-up air systems for hoods above a certain CFM threshold — often 400 or 600 CFM, depending on the local code. A make-up air system introduces filtered outdoor air into the kitchen or HVAC system to balance the exhaust. If your calculated CFM exceeds the threshold for your area, plan for make-up air. This is especially important with gas ranges, because backdrafting can pull combustion byproducts into the home. The calculator flags when the recommended CFM is likely to require make-up air, but always check with your local building department and an HVAC professional.
Noise, Sones, and Why High CFM Is Not Always Better
Range hood noise is rated in sones, and it scales with airflow. A hood that is quiet at 200 CFM may become loud at 600 CFM, and a hood rated at 900 CFM can be unpleasant to run at full speed for long periods. Many homeowners end up running a powerful hood at low speed most of the time — which defeats the purpose of buying a high-CFM unit. Look for a hood with a good noise rating at the speed you will actually use, typically the middle speed. Sone ratings below 3 are generally considered quiet, while ratings above 6 are loud. Some premium hoods use baffle filters and larger ducting to move more air at lower noise levels, which is often a better investment than simply buying the highest CFM. The calculator does not model noise, but it is worth considering: a well-sized 600 CFM hood with 8-inch ducting will be quieter and more effective than a 900 CFM hood squeezed into a 6-inch duct.
Electric, Induction, and Gas: Different Ventilation Needs
Gas cooking produces combustion byproducts — carbon monoxide, nitrogen dioxide, and water vapor — in addition to smoke and grease, so ventilation is a health issue as well as a comfort issue. Electric and induction cooktops produce no combustion gases, so the ventilation requirement is driven by moisture, odors, and grease. That does not mean an electric cooktop needs no hood: searing and frying still produce smoke and grease that settle on cabinets and walls. But the CFM requirement for electric is generally lower than for a comparable gas cooktop. For induction, the lack of waste heat means the plume is smaller, so a hood can often be more effective with less CFM. This calculator applies the BTU-based rule to gas and high-output gas styles, and the width-based rule to electric and induction. If you are switching from gas to induction, you may be able to use a smaller hood — but do not go below the width rule, because the capture area still matters.
How to Measure and Plan Your Installation
Start by measuring your cooktop width and the total BTU output of your burners, which is usually printed on the rating plate or in the owner's manual. Measure the mounting height: most residential hoods are installed 24–30 inches above the cooking surface for electric cooktops and 27–36 inches for gas cooktops, though manufacturer instructions vary. Higher mounting reduces capture effectiveness, so a hood installed at the top of its range may need extra CFM. Plan the duct route: the shortest, straightest path to the outside is best, and each elbow should be counted as extra resistance. Confirm the duct size needed for your CFM — 6-inch for most residential hoods, 8-inch for high-CFM pro hoods. Check the make-up air requirement for your local code. Finally, confirm the electrical requirements: most hoods run on 120 V and draw a few amps, but high-CFM models may need a dedicated circuit. The calculator combines these factors into a single recommendation, but the installation manual for your specific hood is the final authority.
Range Hood Size Calculator Checklist
- Measure cooktop width — the hood should be equal or wider
- Add 3–6 inches of width for better capture, especially on islands
- Calculate CFM: 100 CFM per 10,000 BTU for gas, ~10 CFM per inch for electric
- Add 20–30% for wok cooking or high-heat searing
- Use at least 6-inch duct for hoods above 400 CFM; 8-inch for 900+ CFM
- Count elbows — each adds resistance equivalent to several feet of duct
- Check the airflow rating at 0.25 in. w.g., not just free-air CFM
- Plan for make-up air if CFM exceeds local code thresholds
- Look at sone ratings at the speed you will use most
- Confirm mounting height and electrical requirements
Final Thoughts: Matching Ventilation to the Way You Cook
The right range hood is the one that captures the smoke, steam, and grease your cooking produces, without being so loud that you avoid using it. This calculator gives you a data-driven starting point based on cooktop width, burner output, hood type, and ducting, but the final decision should consider the way you actually cook and the constraints of your kitchen. If you mostly simmer and reheat, a 300 CFM hood with a 6-inch duct may be perfect. If you sear, wok, or cook with a pro range, you need a wider hood, more CFM, larger ducting, and probably make-up air. Whatever you choose, size the duct generously, mount the hood at the recommended height, and verify the real-world performance at a realistic static pressure. With the right sizing and a little planning, your range hood will keep your kitchen clean and comfortable for years.